C1-3000-0200/9999  - Ascon Malaysia  Sales

BRAND Ascon
Product C1-3000-0200/9999
Internal code IMP219280
Weight 1
Technical specification C1 series temperature controller A.No.: G.No.: Front: 48x24 mm (W x H) Supply voltage: 100... 240 V, 50/60 Hz Main output OP1: relay Auxiliary output OP2: logic Serial port: without Interface protocol: none Actual value output OP4: without User manual: German Front color: dark gray Can be freely configured as follows: Input: PT100; thermocouple type L, J, T, K, S; 0 (10)... 50 mV DC OP1 output: relay (2A/250V closer) OP2 output: logic (0/5VDC, + -10%, 30mA max.) Output OP4: without control: PID, heating or cooling, Assignment: 1 output for control and 1 output as alarm or both outputs as an alarm Options: actual value output, transmitter supply or serial port

Please Contact Us to Order to offer competitive prices and delivery time for Ascon - C1-3000-0200/9999 number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Malaysia Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Ascon

MS30/099

Policy

MS-30/30 ABA(replaced by MS-32/.9999)

Configuration 99/99 Power supply 100/240V

MS-30/9999/ADM

(Digital Controls MS (series unconfigured) - Power supply voltage: 100 ... 240V, 50/60 Hz - Serial interface: 2-wire TTY, ASCII optinoal - Dimensions: 48 x 48 mm DIN, depth 110 mm - Weight approx 200 g - input (configurable): * Pt100 * Thermocouple (L, J, K, S) * Standard signal 0 (4) ... 20 mA or 0 ... 1 (10) V Exit: * Main output Y1: relay or logic * Auxiliary output Y2: Alarm relay - PID control with self-optimization and setpoint ramp - heating or cooling characteristic with alarm output or Heating / cooling characteristic without alarm output configurable - Simultaneous display of set and actual values - control output configurable as relays or logic signal - ramp function - Power limitation - scalable inputs for standard signals - configuration via front keys - Voltage output for external 24 V - Transmitter - Parameter lock - Front protection: IP 54, with transparent cover IP 65 (optional) - Customs number: 9032/1020)

MS-32/9999

Digital controller

MS-50/9999

Digitalregler der Serie MS

PT100

Temp. resistence detector ZTR-23M/1P.

PT100-ZTR-23M1/1P/002200

Thermoresistance

QF-3000

universal controller series QF

QF-5000/0

Ascon controller series Gamma 1 Type QF-5000/0 Housing dimensions 96x96 mm Single loop Power supply 24 V AC / DC

RB1A60P00B0035F015P

(Thermo resistance EEs-STN 300°C max D. 6 mm Pt100 DIN-IEC 1 EL.3 wires CI.B (1DIN) CERAMIC 750°C max. G.AISI 316 L.35mm 1/4 GAS-L12 (CH-17) spring length 180mm cable 1,5MT split leads)

RQ1S45P80B3000S00

Temperature probe IP67 D 4,5 mm Pt100DIN-IEC 2 EL. A 6 wires (1/3 DIN) Ceramic 750 C max G.AISI 316 L3000mm NO thread NO ext

SCH AC ALI 3

(Power supply card 85/264V -50/60HZ)

SEDA3002SE4

ROTARY ELECTRIC ACTUATOR

SER 20/60024/52 E0000V9

Nm 20/ sec 60/ 90 degree/ -10+50 degree 24 V/ VA 7

TLK48LCR

Controller. series TLK48 TLK48 type-A-B-C-D-E A: Power supply L-24 V AC / DC H-100 .... 240 V AC B: Input C thermocouple, PT100, mV E thermocouple, NTC, PTC, mV I-0/4 ... 20 mA V-0/1 ... 5 V, 10 V 0/2 ... C: Output 1 R relay O logic signal (SSR) D: output 2 R relay O logic signal (SSR) - - not used E: output 3 R relay O logic signal (SSR) - - not used General data -48x48 mm Front size for panel mounting - protection front IP65 with sealing -Serial communication via TTL interface

TLY26-S-

Digital controller for refrigerating units

TLY27-HRR-D02

defrost controller

X1-3100-0200

Temperature controllers X1 (unconfigured) A.Nr .: G.Nr .: Front: Supply voltage: 100 ... 240 V, 50/60 Hz Ausqanqe: 3 relay (2 Schliefser, 1 PDT) and 1 logic output Serial interface: no Interface protocol: no Actual value OP4: no Operating Instructions: German Front color: dark gray Input: * PT100; Thermocouple I, J, T, K, S, B, N, R, W, Special; 0 (10) .. 50 mV DC * Current transformer input for the Lastkreisuberwachung Control: 10 ... 100A (sec 50/100 mAl. PID, heating 1 Kuhlen,

Other Category Brands

Contact us for request